KEMA 630A 40.5KV IP54 GFM Non Segregated Busway
product detail
KEMA 630A 40.5KV IP54 GFM Non Segregated Busway
Description
Conductor Type: | Enclosed Busduct | Rated Current: | 630A--6300A |
Frequency: | 50Hz/60Hz | IP: | IP54 |
Product Series: | Nonsegregated Busduct/ Segregated Phase Busduct | Design Criteria: | GB/T 8349 |
Product Type: | TMY/LMY | ||
High Light: | IP54 non segregated busway, 630A Medium Voltage Busway, UL non segregated busway |
GFM non-segregated busway,3.6-40.5KV,IP54
Standards | IEC364-5-54/GB/T8349-2000/JB/T9639-1999 | ||||
Ambient | ℃ | ||||
Relative humidity | Daily averages ≤ 95%. Monthly average ≤ 90% | ||||
IP | IP40, IP54 | ||||
Rated voltage | kV | 3.15 | 6.3 | 10.5 | 35 |
Max operating voltage | kV | 3.6 | 7.2 | 12 | 40.5 |
Insulation level | kV | 25/40 | 32/60 | 42/75 | 100/185 |
Rated frequency | Hz | 50(60) | |||
Rated operating current | Dimension (W×H)(mm×mm) | ||||
1000-3000 | A | I 750×400 II 850×350 | I 900×560 II 1060×460 | I 900×560 II 1060×460 | I 1500×920 II 1800×880 |
3500 | A | I 750×440 II 850×480 | I 900×560 II 1060×460 | I 900×560 II 1060×460 | |
4000 | A | I 750×440 II 850×480 | I 900×560 II 1060×460 | I 900×560 II 1060×460 | |
4500 | A | I 750×440 | I 1000×560 | I 1000×560 | |
5000 | A | I 1350×500 | I 1500×600 | I 1500×600 | |
6300-6800 | A | I 1350×500 | I 1500×600 | I 1500×600 |
GFM Series non-segregated phase busway is suitable for transmission system, which provides consistent strength and high short-circuit ratings.
Flexible braided straps are applied to eliminate the vibration of connected equipment. Rubber gaskets are adopted as shock absorber in the system to provide the elastic support to the insulator and the conductor. Moreover, the shock absorber can avoid the machinery vibration caused by equipment and the damage caused by earthquake.
In winter, segregation device can be applied in the wall to avoid condensation happened due to temperature variation between indoor and outdoor in winter.
Silver-plating is applied to all joint and connection area. Silver-plating provides an extremely durable contact surface with better performance of lower contact resistance and anti-corrosion.
Observation window can be installed in the connection area of busduct and transformer cabinet and generator cabinet, distribution cabinet so as to monitor the temperature rise by means of temperature measurement device or online intelligent monitoring system, which greatly improve the level of safety and reliability of operation and maintenance.