Leave Your Message

Air insulated bus duct

The air bus duct is a power transmission device that is cooled by air. Its appearance is similar to a box, and its interior is made of conductive materials with a specially designed design.

Become. In power transmission, air-type bus ducts directly replace traditional cables and busbars, with higher safety, reliability and energy saving.

    Scope Of Application

    High-Rise Building
    Air-type bus duct is suitable for the power supply of high-rise buildings. Due to its characteristics of miniaturization, high efficiency and energy saving, it can meet the power needs of high-rise buildings.

    Large Factory
    For the power supply of large factories, traditional cables and busbars are often difficult to meet the demand. At this time, air-type bus trunking can be used for power transmission to reduce transmission costs.

    Losses And Safety Risks

    Other Places
    Air bus duct is also suitable for other places where power transmission is required, such as airports, overhead passages, etc.

    Summarize
    Air bus duct is a new type of power transmission equipment.  It has the advantages of safety, reliability, high efficiency and energy saving.  It has a wide range of applications in the power supply of high-rise buildings, large factories and other places.

    Extremely Safe And Reliable

    A. Using separated air insulation type, the safe clearance distance and creepage distance between phases are much larger than the standard requirements.

    B. The internal insulation parts are made of high-strength epoxy resin, which improves the vibration resistance and thermal stability of the bus duct.

    Bus ducts of all current levels use unified cover plates, which have a high degree of standardization, strong interchangeability, and convenient variable capacity interfaces.


    The Main Technical Parameters

    Part Name Maximum allowable temperature rise (K)
    Connection terminal 60K
    Metal shell 30K
    Insulating surface 40K
    Rated current(A) Busbar specifications for each phase (mm)
    100 3X30
    250 4X40
    400 6X40
    630 6X50
    800 6X60
    1000 6X80
    1250 6X100
    1600 6X140
    2000 BX140
    2500 BX175
    3150 BX200
    4000 2-8X140
    5000 2-8X175

    Selection And Drawings

    The connection of the bus duct is shown in the figure.

    RTCKX8-2A

    High-Rise Building
    The air busbar measure is suitable for the power supply of high-rise buildings. Due to its characteristics of miniaturization, high efficiency and energy saving, it can meet the power needs of high-rise buildings.

    Large Factory
    For the power supply of large factories, traditional cables and busbars are often difficult to meet the demand. At this time, air-type bus trunking can be used for power transmission to reduce transmission costs.

    Losses And Safety Risks

    Other Places
    Air bus duct is also suitable for other places where power transmission is required, such as airports, overhead passages, etc.

    Summarize
    Air bus duct is a new type of power transmission equipment. It has the advantages of safety, reliability, high efficiency and energy saving. It has a wide range of applications in the power supply of high-rise buildings, large factories and other places.

    Structural Features

    Shell Features
    The shell of this series of bus ducts is made of bent plates, with small size and exquisite appearance; It greatly improves the sub-load capacity. The installation is extremely convenient and adopts the docking installation method, making the motherboard. The wire duct is very convenient and flexible during the installation process, which greatly saves installation time.

    Extremely Safe And Reliable

    A. Using separated air insulation type, the safe clearance distance and creepage distance between phases are much larger than the standard requirements.

    B. The internal insulation parts are made of high-strength epoxy resin, which improves the vibration resistance and thermal stability of the bus duct.

    High Degree Of Standardization

    Bus ducts of all current levels use unified cover plates, which have a high degree of standardization, strong interchangeability, and convenient variable capacity interfaces.

    The main technical parameters

    Conductive parts Maximum allowable temperature rise (K)
    Shell 30
    Insulating material surface 30
    Busbar to busbar connection 60
    The connection between the plug-in box plug and the busbar 60

    Rated current(A) Four wire system Five-wire system
    W(mm) H(mm) Weight(kg/m) W(mm) H(mm) Weight(kg/m)
    200 152 89 16.4 171 89 19.6
    250 152 84 18.2 171 84 21.5
    400 152 94 20.3 171 94 23.6
    630 152 104 22.4 171 104 24.9
    800 152 119 25.6 171 119 28.2
    1000 152 134 28.8 171 134 32.4
    1250 152 169 36.5 171 169 39.1
    1600 152 189 47.1 171 189 51.8
    2000 152 224 56 171 224 61.2
    2500 152 334 68.8 171 334 75.7
    3150 152 374 89.6 171 374 97.5
    4000 152 444 108.5 171 444 115.8

    Due to the unique design style and reasonable structure of RTCKX8-2A high-strength closed bus duct, it combines air type and intensive type.  It is unique among domestic bus duct products because of its significantly superior mechanical properties and The excellent electrical performance makes it widely used in power distribution rooms, basements, and vertical sections in modern high-rise buildings, large factories, substations, power plants and other power supply places such as electric power, petroleum, chemicals, transportation, and civil aviation.

    Busbar functional unit code table

    Code name Name Code name Name
    A Ordinary bus P Expansion joint
    S Starting bus BY Transformer connector
    Z Terminal cover BX Adjustment joint
    LS L-shaped horizontal joint SC Cross vertical joint
    LC L-shaped vertical joint ZS Type B horizontal joint
    TS T-shaped horizontal joint ZC Z type vertical joint
    TC T-type vertical joint SH Starting terminal box

    Selection And Drawings

    ● The bus duct adopts a high-strength fully enclosed structure with a protection level of up to IP30.

    ● The number of plug-and-pull times between the bus duct plug-in box and the bus duct shall not be less than 200 times.

    ● The cross-sectional dimensions and weight per meter of the bus duct are shown in the figure and table below.

    Three-phase four-wire system; Three-phase five-wire system; The connection of the bus duct is shown in Figure (2);

    RTCKX8-2A high-strength closed bus duct structure